Wall R-value calculator for wood-frame walls

Wood Framing Planner works out the R-value, U-factor and condensation risk of every exterior wall from the build-up you choose and the framing it generates - studs, plates and headers included. Then it lays out the sheathing sheet by sheet and counts the insulation you need to buy.

Build the wall up, layer by layer

Every wall gets a build-up: what goes on the outside, in the cavity between the studs, and on the inside. Set it once for the whole house, then give any wall its own where it differs.

Each material comes with typical thermal conductivity and vapour resistance. Type in the values from your product's data sheet, or add a board of your own.

R-value from the real framing, not a rule of thumb

Most wall R-value calculators ask you to guess a framing factor. Wood Framing Planner measures it: the timber share of each wall comes from the frame it generated for that wall, with every stud, plate, header and cripple, around every window and door. A wall full of openings is honestly worse than a blank one.

The result follows the combined method of ISO 6946 - the upper and lower limit, averaged - with the surface resistances on both sides and an option for a ventilated facade. Imperial projects show the assembly R-value and U-factor; metric projects show the U-value in W/(m²·K). The whole house gets an area-weighted average over all exterior walls, with the openings taken out.

Condensation and drying - before it is inside the wall

A wall can be warm and still rot. For every exterior wall the app runs a dew point and vapour diffusion check through the insulated part of the wall:

Inside temperature and humidity, the outside design temperature and both seasons are yours to set for where the house stands.

Judged against your code

Sheathing laid out sheet by sheet

The same build-up drives a real sheet layout on both faces of every wall, like a subfloor layout: sheets standing or lying, joints on stud centres, staggered rows, no slivers at the edge, a clearance around openings, and an overhang down over the rim joist. Openings are cut out, offcuts carry over from wall to wall, and every piece is numbered by the sheet it comes from - 4 is a whole sheet, 4A and 4B are two pieces of sheet 4. The board layout of each wall goes into the PDF, and the layers show in 3D.

Insulation and material cost

Cavity insulation is totalled over every wall and level - by area for batts and rolls, by volume for blown-in and spray foam - and counted in packs. Enter what a pack covers and what it costs, and Materials & Cost prices the timber, the sheets and the insulation together, with a reserve you choose for each material.

What is free

Building up the walls, picking materials and setting the climate are free. The R-value, U-factor and condensation result of the first exterior wall are free to see; every other wall, the piece numbers on every sheet and the PDF pages come with Pro.

An estimate by ISO 6946 and the Glaser method (EN ISO 13788), with the year's moisture balance on the DIN 4108-3 block climate. Thermal bridges at corners, openings and junctions are not included. Have the design checked by a qualified professional.

Questions

What is the R-value of a 2x6 wall?

It depends on what is in it. The insulation in the cavity, the boards on both faces and how much of the wall is solid timber all change the result. Studs, plates and headers carry far more heat than the insulation between them, so a 2x6 wall with R-21 batts comes out well below R-21. Wood Framing Planner works it out from your own build-up and the framing it generates for that wall.

Does the calculator account for thermal bridging through the studs?

Yes. The timber share of every wall is measured from its generated frame - every stud, plate, header and cripple - and combined with the insulation using the ISO 6946 method. Linear thermal bridges at corners, window reveals and junctions are not included yet.

What's the difference between R-value and U-value?

R-value is how well a wall resists heat flow; U-value (U-factor) is how much heat gets through it. One is the inverse of the other: U = 1 / R. US codes give R-values in ft²·°F·h/Btu, European codes give U-values in W/(m²·K). The app shows whichever matches your project units.

Will my wall have a condensation problem?

The app checks it with the Glaser method (EN ISO 13788) on the coldest design day, and over a winter and a drying season on the DIN 4108-3 climate. It shows whether vapour condenses, in which layer, how much over the winter and whether it dries out again - so you can add a vapour retarder inside or choose a more open board outside before you build.

Does it replace an energy assessment?

No. The results are an estimate for planning and comparing build-ups. Have the final design checked by an energy rater, building physicist or engineer as your local rules require.

Check your walls before you build

GET IT ON Google Play DOWNLOAD ON THE App Store WEB APP Open in browser Coming soon